1.
Lasers Med Sci ; 38(1): 210, 2023 Sep 12.
Article in English | MEDLINE | ID: mdl-37698685

ABSTRACT

Since the beginning of the COVID-19 pandemic, the scientific community has sought to develop fast and accurate techniques for detecting the SARS-CoV-2 virus. Raman spectroscopy is a promising technique for diagnosing COVID-19 through serum samples. In the present study, the diagnosis of COVID-19 through nasopharyngeal secretion has been proposed. Raman spectra from nasopharyngeal secretion samples (15 Control, negative and 12 COVID-19, positive, assayed by immunofluorescence antigen test) were obtained in triplicate in a dispersive Raman spectrometer (830 nm, 350 mW), accounting for a total of 80 spectra. Using principal component analysis (PCA) the main spectral differences between the Control and COVID-19 samples were attributed to N and S proteins from the virus in the COVID-19 group. Features assigned to mucin (serine, threonine and proline amino acids) were observed in the Control group. A binary model based on partial least squares discriminant analysis (PLS-DA) differentiated COVID-19 versus Control samples with accuracy of 91%, sensitivity of 80% and specificity of 100%. Raman spectroscopy has a great potential for becoming a technique of choice for rapid and label-free evaluation of nasopharyngeal secretion for COVID-19 diagnosis.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , Feasibility Studies , SARS-CoV-2 , Spectrum Analysis, Raman , COVID-19 Testing , Pandemics
2.
J Photochem Photobiol B ; 238: 112619, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36495670

ABSTRACT

BACKGROUND: COVID-19 disease is caused by SARS-CoV-2 which can trigger acute respiratory syndrome, which presents with dense alveolar and interstitial infiltrates and pulmonary edema, causing severe hypoxemia and significant alteration to pulmonary mechanics with reduced pulmonary compliance. The photobiomodulation technique alters cellular and molecular metabolism, showing promising results regarding the reduction of acute pulmonary inflammation. OBJECTIVE: To compare the photomodulation technique using near-infrared LED to conventional respiratory physiotherapy treatment in patients with COVID-19 in reversing acute conditions, reducing hospitalization time, and decreasing the need for oxygen therapy. METHODOLOGY: The cohort was comprised of 30 patients undergoing COVID-19 treatment who were divided and allocated into two equal groups randomly: the LED group (LED), treated with infrared LED at 940 nm and conventional therapy, and the control group (CON), who received conventional treatment (antibiotic therapy for preventing superimposed bacterial infections, and physiotherapy) with LED irradiation off. Phototherapy used a vest with an array of 300 LEDs (940 nm) mounted on a 36 cm × 58 cm area and positioned in the patient's anterior thoracic and abdominal regions. The total power was 6 W, with 15 min irradiation time. Cardiopulmonary functions and blood count were monitored before and after treatment. The patients were treated daily for 7 days. Statistical analysis was conducted using a two-tailed unpaired Student's t-test at a significance level of α = 0.05. RESULTS: Post-treatment, the LED group showed a reduction in hospital discharge time and a statistically significant improvement for the following cardiopulmonary functions: Partial Oxygen Saturation, Tidal Volume, Maximum Inspiratory, and Expiratory Pressures, Respiratory Frequency, Heart Rate, and Systolic Blood Pressure (p < 0.05). Regarding blood count, it was observed that post-treatment, the LED group presented with significant differences in the count of leukocytes, neutrophils, and lymphocytes. CONCLUSION: Photobiomodulation therapy can be used as a complement to conventional treatment of COVID-19, promoting the improvement of cardiopulmonary functions, and minimization of respiratory symptoms.


Subject(s)
COVID-19 , Humans , SARS-CoV-2 , RNA, Viral , COVID-19 Drug Treatment , Lung
3.
Lasers Med Sci ; 37(4): 2217-2226, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35028768

ABSTRACT

This study proposed the diagnosis of COVID-19 by means of Raman spectroscopy. Samples of blood serum from 10 patients positive and 10 patients negative for COVID-19 by RT-PCR RNA and ELISA tests were analyzed. Raman spectra were obtained with a dispersive Raman spectrometer (830 nm, 350 mW) in triplicate, being submitted to exploratory analysis with principal component analysis (PCA) to identify the spectral differences and discriminant analysis with PCA (PCA-DA) and partial least squares (PLS-DA) for classification of the blood serum spectra into Control and COVID-19. The spectra of both groups positive and negative for COVID-19 showed peaks referred to the basal constitution of the serum (mainly albumin). The difference spectra showed decrease in the peaks referred to proteins and amino acids for the group positive. PCA variables showed more detailed spectral differences related to the biochemical alterations due to the COVID-19 such as increase in lipids, nitrogen compounds (urea and amines/amides) and nucleic acids, and decrease of proteins and amino acids (tryptophan) in the COVID-19 group. The discriminant analysis applied to the principal component loadings (PC2, PC4, PC5, and PC6) could classify spectra with 87% sensitivity and 100% specificity compared to 95% sensitivity and 100% specificity indicated in the RT-PCR kit leaflet, demonstrating the possibilities of a rapid, label-free, and costless technique for diagnosing COVID-19 infection.


Subject(s)
COVID-19 , Spectrum Analysis, Raman , Amino Acids , COVID-19/diagnosis , Discriminant Analysis , Humans , Principal Component Analysis , Serum , Spectrum Analysis, Raman/methods
4.
Photobiomodul Photomed Laser Surg ; 40(1): 51-58, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34935510

ABSTRACT

Background: The analysis of the complete blood count (CBC) of patients with community-acquired pneumonia (CAP) is an essential practice both for diagnosing the disease and for evaluating the patient's clinical evolution. It is proposed in the present study to analyze the hematological alterations resulting from photobiostimulation using near-infrared light-emitting diodes (LEDs) in patients with CAP. Methods: This was a clinical, prospective, blinded, and descriptive longitudinal study that involved 21 patients undergoing CAP treatment who were divided into two groups: LED, 11 patients who were treated with infrared LED and conventional treatment; and CON (control), 10 patients who received only conventional treatment (antibiotic therapy and physiotherapy). Physiotherapy was applied before LED irradiation in the LED group. The patients' CBCs were obtained before and after treatment, and erythrocyte counts, hemoglobin and hematocrit concentrations, and leukocyte and platelet counts were assessed. The phototherapy was performed with a vest with an array of 300 LEDs (940 nm) mounted on an area of 36 × 58 cm and positioned in the patient's anterior thoracic and abdominal regions. The total power was 6 W, with 15 min of irradiation time. The patients were treated daily for seven consecutive days. Statistical analyses of the intra- and intergroups of CBC data were done using Student's t-test and one-way ANOVA (analysis of variance), respectively, both at the significance level of α = 0.05. Results: There was a statistically significant recovery difference after treatment in the LED group compared with the CON group for erythrocytes, hemoglobin, leukocytes, segmented and band neutrophils, lymphocytes, and monocytes (p < 0.05). The greatest differences between the LED and CON groups were lymphocyte count reduction (60% vs. 16%), erythrocyte increase (86% vs. 35%), and leukocyte reduction (28% vs. 15%). Conclusions: The hematologic components of CAP patients recovered their normal values faster with conventional treatment associated with infrared LED therapy, thus indicating greater treatment efficiency when compared with the conventional therapy. This study was registered with the Brazilian Registry of Clinical Trials (ReBeC) under Universal Trial Number (UTN) U1111-1229-1296 (2019/06/05).


Subject(s)
Community-Acquired Infections , Pneumonia , Community-Acquired Infections/therapy , Humans , Longitudinal Studies , Neutrophils , Prospective Studies
5.
J Raman Spectrosc ; 52(12): 2671-2682, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34518728

ABSTRACT

The severe COVID-19 pandemic requires the development of novel, rapid, accurate, and label-free techniques that facilitate the detection and discrimination of SARS-CoV-2 infected subjects. Raman spectroscopy has been used to diagnose COVID-19 in serum samples of suspected patients without clinical symptoms of COVID-19 but presented positive immunoglobulins M and G (IgM and IgG) assays versus Control (negative IgM and IgG). A dispersive Raman spectrometer (830 nm, 350 mW) was employed, and triplicate spectra were obtained. A total of 278 spectra were used from 94 serum samples (54 Control and 40 COVID-19). The main spectral differences between the positive IgM and IgG versus Control, evaluated by principal component analysis (PCA), were features assigned to proteins including albumin (lower in the group COVID-19 and in the group IgM/IgG and IgG positive) and features assigned to lipids, phospholipids, and carotenoids (higher the group COVID-19 and in the group IgM/IgG positive). Features referred to nucleic acids, tryptophan, and immunoglobulins were also seen (higher the group COVID-19). A discriminant model based on partial least squares regression (PLS-DA) found sensitivity of 84.0%, specificity of 95.0%, and accuracy of 90.3% for discriminating positive Ig groups versus Control. When considering individual Ig group versus Control, it was found sensitivity of 77.3%, specificity of 97.5%, and accuracy of 88.8%. The higher classification error was found for the IgM group (no success classification). Raman spectroscopy may become a technique of choice for rapid serological evaluation aiming COVID-19 diagnosis, mainly detecting the presence of IgM/IgG and IgG after COVID-19 infection.

6.
Nat Commun ; 12(1): 418, 2021 01 18.
Article in English | MEDLINE | ID: mdl-33462211

ABSTRACT

With COVID-19 surging across the world, understanding the effectiveness of intervention strategies on transmission dynamics is of primary global health importance. Here, we develop and analyze an epidemiological compartmental model using multi-objective genetic algorithm design optimization to compare scenarios related to strategy type, the extent of social distancing, time window, and personal protection levels on the transmission dynamics of COVID-19 in São Paulo, Brazil. The results indicate that the optimal strategy for São Paulo is to reduce social distancing over time with a stepping-down reduction in the magnitude of social distancing every 80-days. Our results also indicate that the ability to reduce social distancing depends on a 5-10% increase in the current percentage of people strictly following protective guidelines, highlighting the importance of protective behavior in controlling the pandemic. Our framework can be extended to model transmission dynamics for other countries, regions, states, cities, and organizations.


Subject(s)
Algorithms , COVID-19/prevention & control , Models, Theoretical , SARS-CoV-2/isolation & purification , Brazil/epidemiology , COVID-19/epidemiology , COVID-19/virology , Cities , Global Health , Humans , Pandemics , Physical Distancing , SARS-CoV-2/physiology , Urban Health/statistics & numerical data
7.
Photobiomodul Photomed Laser Surg ; 38(7): 395-397, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32579049

ABSTRACT

Objective: To evaluate the hypothesis that light could reduce the lethality of COVID-19. Methods: Most models for projections of the spread and lethality of COVID-19 take into account the ambient temperature, neglecting light. Recent advances in understanding the mechanism of action of COVID-19 have shown that it causes a systemic infection that significantly affects the hematopoietic system and hemostasis, factors extremely dependent of light, mainly in the region of visible and infrared radiation. Results: In the COVID-19 patients hemoglobin is decreasing and protoporphyrin is increasing, generating an extremely harmful accumulation of iron ions in the bloodstream, which are able to induce an intense inflammatory process in the body with a consequent increase in C-reactive protein and albumin. Observing the unsaturation characteristics of the cyclic porphyrin ring allows it to absorb and emit radiation mainly in the visible region. This characteristic can represent an important differential to change this process in the event of an imbalance in this system, through the photobiomodulation to increase the production of adenosine triphosphate (ATP) using red and near-infrared radiation (R-NIR) and vitamin D using ultraviolet B (UVB) radiation. These two compounds have the primary role of activating the defense mechanisms of the immune system, enabling greater resistance of the individual against the attack by the virus. According to the theory of electron excitation in photosensitive molecules, similar to hemoglobin heme, after the photon absorption there would be an increase in the stability of the iron ion bond with the center of the pyrrole ring, preventing the losses of heme function oxygen transport (HbO2). The light is also absorbed by cytochrome c oxidase in the R-NIR region, with a consequent increase in electron transport, regulating enzyme activity and resulting in a significant increase of oxygen rate consumption by mitochondria, increasing ATP production. Conclusions: The most favorable range of optical radiation to operate in this system is between R-NIR region, in which cytochrome c oxidase and porphyrin present absorption peaks centered at 640 nm and HbO2 with absorption peak centered at 900 nm. Based on the mechanisms described earlier, our hypothesis is that light could reduce the lethality of COVID-19.


Subject(s)
Betacoronavirus , Coronavirus Infections/radiotherapy , Low-Level Light Therapy , Pneumonia, Viral/radiotherapy , Ultraviolet Therapy , COVID-19 , Humans , Infrared Rays/therapeutic use , Pandemics , SARS-CoV-2 , Ultraviolet Rays
8.
Lasers Med Sci ; 35(5): 1141-1151, 2020 Jul.
Article in English | MEDLINE | ID: mdl-31853808

ABSTRACT

The differences in the biochemistry of normal and cancerous tissue could be better exploited by Raman spectroscopy when the spectral information from normal tissue is subtracted from the abnormal tissues. In this study, we evaluated the use of the normal-subtracted spectra to evidence the biochemical differences in the pre-cancerous and cancerous skin tissues compared with normal skin, and to discriminate the groups with altered tissues with respect to the normal sites. Raman spectra from skin tissues [normal (Normal), benign (dermatitis-BEN), basal cell carcinoma (BCC), squamous cell carcinoma (SCC), and actinic keratosis (KER)] were obtained in vivo (Silveira et al., 2015, doi: https://doi.org/10.1002/lsm.22318) and used to develop the spectral model. The mean spectrum of the normal sites (circumjacent to each lesion) from each subject was calculated and subtracted from each individual spectrum of that particular subject independently of the group (Normal, BEN, BCC, SCC, KERAT). The mean spectra of each altered group and the mean spectra of the differences were firstly evaluated in terms of biochemical contribution or differentiation comparing the normal site. Then, the normal-subtracted spectra were submitted to discriminant models based on partial least squares and principal components regression (PLS-DA and PCR-DA), and the discrimination were compared with the model using non-subtracted spectra. Results showed that the peaks of nucleic acids, lipids (triolein) and proteins (elastin and collagens I, III, and IV) were significantly different in the lesions, higher for the pre- and neoplastic lesions compared with normal and benign. The PLS-DA showed that the groups could be discriminated with 90.3% accuracy when the mean-subtracted spectra were used, contrasting with 75.1% accuracy when the non-subtracted spectra were used. Also, when discriminating non-neoplastic tissue (Normal + BEN) from pre- and neoplastic sites (BCC + SCC + KERAT), the accuracy increases to 92.5% for the normal-subtracted compared with 85.3% for the non-subtracted. The subtraction of the mean normal spectrum from the subject obtained circumjacent to each lesion could significantly increase the diagnostic capability of the Raman-based discrimination algorithm.


Subject(s)
Algorithms , Keratosis, Actinic/diagnosis , Skin Neoplasms/diagnosis , Skin/diagnostic imaging , Skin/pathology , Spectrum Analysis, Raman , Carcinoma, Basal Cell/diagnosis , Carcinoma, Basal Cell/diagnostic imaging , Carcinoma, Squamous Cell/diagnosis , Carcinoma, Squamous Cell/diagnostic imaging , Discriminant Analysis , Humans , Least-Squares Analysis , Principal Component Analysis
9.
Photobiomodul Photomed Laser Surg ; 37(10): 657-666, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31647777

ABSTRACT

Objective: This research evaluated the hemodynamic conditions before and after the transcranial photobiomodulation therapy (PBMT) and investigated neurocognitive changes before and after treatment. Background: Traumatic brain injury (TBI) is the major cause of morbidity and mortality among individuals 21-60 years old and causes ∼500,000 people to be hospitalized in Brazil annually. Some survivors develop an irreversible decrease in neurological function, and the mortality rate is as high as 70% in severe cases. PBMT is an alternative to treat secondary injuries due to TBI. Methods: This multidisciplinary clinical study was carried out on 10 chronic adult patients with severe TBI, who were treated with PBMT with an optical device containing 13 sets of 4 light emitting diodes, and underwent hemodynamic transcranial Doppler and neuropsychological evaluation at three different times: pre-PBMT, post-PBMT (after a week), and late-PBMT, which occurred 3 months after the last session. The patients received PBMTs three times a week, for 6 weeks. PBMTs were performed for 18 sessions for 6 weeks and 30 min per session. Results: The results found an alteration in the cerebral blood flow (CBF) as well as a consequent increase of the cerebral oxygenation that helped to improve the cerebral function. Conclusions: The PBMT contributed to increased CBF, evidenced mainly by the increased left peak systolic velocity, which consequently increased the hemodynamic response after the PBMT and impacts on the peripheral cerebral perfusion contributing to improved cerebral function.


Subject(s)
Brain Injuries, Traumatic/diagnostic imaging , Brain Injuries, Traumatic/rehabilitation , Brain Injuries, Traumatic/radiotherapy , Cerebrovascular Circulation/radiation effects , Low-Level Light Therapy/methods , Adult , Brazil , Cerebrovascular Circulation/physiology , Chronic Disease , Cognition/radiation effects , Cohort Studies , Disability Evaluation , Female , Follow-Up Studies , Humans , Injury Severity Score , Magnetic Resonance Imaging/methods , Male , Middle Aged , Neuropsychological Tests , Retrospective Studies , Time Factors , Treatment Outcome , Ultrasonography, Doppler/methods , Young Adult
10.
Medicine (Baltimore) ; 98(19): e15666, 2019 May.
Article in English | MEDLINE | ID: mdl-31083270

ABSTRACT

The purpose of this observational study was to examine the prevalence of obesity in children of 6 to 8 years of age from primary public schools over a period of 6 years and the associated environmental and metabolic health risk factors.This was a cohort observational study to investigate the prevalence of obesity in children from 14 state primary schools in Vinhedo, Sao Paulo state. Environmental and metabolic health risk factors for obesity were investigated in a cross-sectional survey.This present study revealed 74.0% of children with obesity consumed fried foods and sweets at school, and 84.0% consumed snacks and soft drinks at home. This cohort reported to have engaged in physical activity for less than 3 hours per week at school (93.0%) and at home (85.0%). There was a high prevalence of increased waist circumference and insulin resistance among children with obesity (84.9% and 84.5%, respectively). The body mass index had a significant Spearman correlation with waist circumference, insulin resistance, and triglycerides.Childhood obesity was associated with a high prevalence of both environmental and metabolic risk factors. Also, the authors conclude that the lack of parents' awareness of childhood obesity and its risk factors represents a substantial barrier to lifestyle counseling.


Subject(s)
Metabolic Syndrome/epidemiology , Pediatric Obesity/epidemiology , Body Mass Index , Brazil/epidemiology , Child , Cohort Studies , Diet , Female , Humans , Insulin Resistance , Male , Metabolic Syndrome/pathology , Metabolic Syndrome/physiopathology , Parents/psychology , Pediatric Obesity/pathology , Pediatric Obesity/physiopathology , Prevalence , Risk Factors , Schools , Sedentary Behavior , Waist Circumference
11.
Ozone Sci Eng, v. 41, n. 3, p. 242-249, out. 2019
Article in English | Sec. Est. Saúde SP, SESSP-IBPROD, Sec. Est. Saúde SP | ID: bud-2749

ABSTRACT

Ozonated water has been demonstrated to induce significant results in terms of the elimination ofmicroorganisms. The present study assessed the damage toStreptococcusmutansafter exposureto ozonated water; the ozone generator was adjusted to provide an outlet concentration of60 mg/L, the samples were submitted to different ozonation times 1, 2, 4, 6, and 10 mi. Scanningelectron microscopy and atomic force images were obtained to identify damage to the bacteria,followed by reactive oxygen species (ROS) evaluation and microbial viability. The results showed asignificant reduction in viability and the images evidenced the generation of gaps on themicrobial wall and surface layer alterations. Ozone can induce significant damage toS.mutans,thus suggesting that the use of ozonated water to prevent carious lesion formation is extremelypromising.

12.
Ozone. Sc.i Eng. ; 41(3): p. 242–249, 2019.
Article in English | Sec. Est. Saúde SP, SESSP-IBPROD, Sec. Est. Saúde SP | ID: but-ib15997

ABSTRACT

Ozonated water has been demonstrated to induce significant results in terms of the elimination ofmicroorganisms. The present study assessed the damage toStreptococcusmutansafter exposureto ozonated water; the ozone generator was adjusted to provide an outlet concentration of60 mg/L, the samples were submitted to different ozonation times 1, 2, 4, 6, and 10 mi. Scanningelectron microscopy and atomic force images were obtained to identify damage to the bacteria,followed by reactive oxygen species (ROS) evaluation and microbial viability. The results showed asignificant reduction in viability and the images evidenced the generation of gaps on themicrobial wall and surface layer alterations. Ozone can induce significant damage toS.mutans,thus suggesting that the use of ozonated water to prevent carious lesion formation is extremelypromising.

13.
Braz Oral Res ; 32: e61, 2018 Oct 25.
Article in English | MEDLINE | ID: mdl-30379208

ABSTRACT

To evaluate the impact of the GaAlAs diode laser with energy densities of 160 J/cm2, 320 J/cm2, and 640 J/cm2 on the periodontal tissues under continuous orthodontic force application and on the rate of orthodontic tooth movement in rats with type-2 diabetes mellitus. The intensity of primary alveolar bone formation was also investigated through the immune-positive osteocytes for OPN antibody. Forty adult male Wistar rats were divided into eight groups of 5 rats: normoglycemic (N), 160 J-laser-normoglycemic (160 J-LN), 320 J-laser-normoglycemic (320 J-LN), 640 J-laser-normoglycemic (640 J-LN), diabetic (D), 160 J-laser-diabetic (160 J-LD), 320 J-laser-diabetic (320 J-LD), and 640 J-laser-diabetic (640 J-LD) rats. Diabetes mellitus was induced by a single intravenous injection of 40 mg/kg monohydrated-alloxan. An orthodontic force magnitude of 20cN was applied. The laser parameters were continuous emission of 780-nm wavelength, output power of 20mW, and fiber probe with a spot size of 0.04 cm in diameter. Radiographic, histomorphological, and immunohistochemical analysis were performed after a period of 21 days. The photobiomodulation using the energy density of 640 J/cm2 strongly stimulated the alveolar bone formation and contributed the reorganization of the soft periodontal tissues, followed by the 320 J/cm2. Extensive alveolar bone loss, intense infiltration of inflammatory cells, and degradation of the PDJ tissue were mainly found in the D and 160 J-LD groups. The rate of orthodontic tooth movement was represented by the interdental distance between the cementoenamel junctions of the right mandibular first and second molars . This distance was larger in the diabetic groups (D: 39.98±1.97, 160 J-LD: 34.84±6.01, 320 J-LD: 29.82±1.73, and 640 J-LD: 35.47±4.56) than in the normoglycemic groups (N: 21.13±1.19; 160 J-LN: 22.69±0.72, 320 J-LN: 22.28±0.78, and 640 J-LN: 24.56±2.11). The number of osteopontin-positive osteocytes was significantly greater in the 640 J-LD (14.72 ± 0.82; p < 0.01) and 640 J-LN (13.62 ± 1.33; p < 0.05) groups than with D (9.82 ± 1.17) and 160 J-LD (9.77 ± 1.10) groups. Therefore, the energy density of 640 J/cm2 provided the best maintenance and integrity of the periodontal tissue microarchitecture under continuous orthodontic force when compared with the other dosages, mainly in the uncontrolled diabetic rats. The interdental distance was greater in the D and 160 J-LD groups due to presence of severe periodontitis caused by diabetes plus the mechanical stress generated by continuous orthodontic forces, implying, thus, an insufficient biostimulatory effect for the dosage of 160 J/cm2.


Subject(s)
Diabetes Mellitus, Type 2/physiopathology , Low-Level Light Therapy/methods , Periodontium/radiation effects , Tooth Movement Techniques/methods , Alveolar Bone Loss/pathology , Animals , Diabetes Mellitus, Experimental , Immunohistochemistry , Lasers, Semiconductor/therapeutic use , Male , Orthodontic Appliances , Osteoclasts/radiation effects , Osteocytes/radiation effects , Osteogenesis/radiation effects , Osteopontin/analysis , Periodontium/diagnostic imaging , Periodontium/pathology , Radiation Dosage , Radiography , Random Allocation , Rats, Wistar , Reference Values , Reproducibility of Results
14.
Lasers Med Sci ; 33(7): 1537-1547, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29704068

ABSTRACT

Many studies have been conducted on the treatment of burns because they are important in morbidity and mortality. These studies are mainly focused on improving care and quality of life of patients. The aim of this study was evaluate the LED phototherapy effects in rats skin full-thickness burns induced by CO2 laser. The animals were divided in NT group that did not received any treatment and LED group that received LED irradiation at 685 nm, 220 mW, and 4.5 J/cm2 during 40 s by burned area. Biopsies were obtained after 7, 14, and 21 days of treatment and submitted to histological and immunohistochemical analysis. The LED phototherapy shows anti-inflammatory effects, improves angiogenesis, and stimulates the migration and proliferation of fibroblasts. The T CD8+ lymphocytes were more common in burned areas compared to T CD4+ lymphocytes since statistically significant differences were observed in the LED group compared to the NT group after 7 days of treatment. These results showed that LED phototherapy performs positive influence in full-thickness burns repair from the healing process modulated by cellular immune response. The obtained results allowed inferring that burns exhibit a characteristic cell immune response and this cannot be extrapolated to other wounds such as incision and wounds induced by punch, among others.


Subject(s)
Burns/etiology , Burns/radiotherapy , Lasers, Gas/adverse effects , Phototherapy/methods , Skin/pathology , Skin/radiation effects , Animals , Burns/pathology , Fibroblasts/pathology , Fibroblasts/radiation effects , Male , Rats, Wistar , T-Lymphocytes/pathology , T-Lymphocytes/radiation effects , Wound Healing/radiation effects
15.
Trials ; 19(1): 249, 2018 Apr 24.
Article in English | MEDLINE | ID: mdl-29690927

ABSTRACT

BACKGROUND: Photobiomodulation describes the use of red or near-infrared light to stimulate or regenerate tissue. It was discovered that near-infrared wavelengths (800-900 nm) and red (600 nm) light-emitting diodes (LED) are able to penetrate through the scalp and skull and have the potential to improve the subnormal cellular activity of compromised brain tissue. Different experimental and clinical studies were performed to test LED therapy for traumatic brain injury (TBI) with promising results. One of the proposals of this present study is to develop different approaches to maximize the positive effects of this therapy and improve the quality of life of TBI patients. METHODS/DESIGN: This is a double-blinded, randomized, controlled trial of patients with diffuse axonal injury (DAI) due to a severe TBI in an acute stage (less than 8 h). Thirty two patients will be randomized to active coil helmet and inactive coil (sham) groups in a 1:1 ratio. The protocol includes 18 sessions of transcranial LED stimulation (627 nm, 70 mW/cm2, 10 J/cm2) at four points of the frontal and parietal regions for 30 s each, totaling 120 s, three times per week for 6 weeks, lasting 30 min. Patients will be evaluated with the Glasgow Outcome Scale Extended (GOSE) before stimulation and 1, 3, and 6 months after the first stimulation. The study hypotheses are as follows: (1) transcranial LED therapy (TCLT) will improve the cognitive function of DAI patients and (2) TCLT will promote beneficial hemodynamic changes in cerebral circulation. DISCUSSION: This study evaluates early and delayed effects of TCLT on the cognitive rehabilitation for DAI following severe acute TBI. There is a paucity of studies regarding the use of this therapy for cognitive improvement in TBI. There are some experimental studies and case series presenting interesting results for TBI cognitive improvement but no clinical trials. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03281759 . Registered on 13 September 2017.


Subject(s)
Brain Injuries, Traumatic/radiotherapy , Brain/radiation effects , Cognition/radiation effects , Diffuse Axonal Injury/radiotherapy , Lasers, Semiconductor/therapeutic use , Low-Level Light Therapy/instrumentation , Adolescent , Adult , Brain/blood supply , Brain/physiopathology , Brain Injuries, Traumatic/diagnosis , Brain Injuries, Traumatic/physiopathology , Brain Injuries, Traumatic/psychology , Brazil , Cerebrovascular Circulation/radiation effects , Diffuse Axonal Injury/diagnosis , Diffuse Axonal Injury/physiopathology , Diffuse Axonal Injury/psychology , Double-Blind Method , Female , Glasgow Coma Scale , Humans , Lasers, Semiconductor/adverse effects , Low-Level Light Therapy/adverse effects , Male , Middle Aged , Neurologic Examination , Quality of Life , Randomized Controlled Trials as Topic , Recovery of Function , Time Factors , Treatment Outcome , Young Adult
16.
Trials ; 19(1): 17, 2018 Jan 08.
Article in English | MEDLINE | ID: mdl-29310710

ABSTRACT

BACKGROUND: Photobiomodulation using low-level laser therapy (LLLT) has been tested as a new technique to optimize recovery of patients with traumatic brain injury (TBI). The aim of this study is to evaluate inhibitory attentional control after 18 sessions of active LLLT and compare with the placebo group (sham LLLT). Our exploratory analysis will evaluate the efficacy of the active LLLT on verbal and visuospatial episodic memory, executive functions (working memory, verbal and visuospatial fluency, attentional processes), and anxiety and depressive symptoms compared to the sham group. METHODS/DESIGN: A randomized double-blinded trial will be made in 36 patients with moderate and severe TBI. The active LLLT will use an optical device composed of LEDs emitting 632 nm of radiation at the site with full potency of 830 mW. The cranial region with an area of 400 cm2 will be irradiated for 30 min, giving a total dose per session of 3.74 J/cm2. The sham LLLT group contains only an LED device with power < 1 mW, only serving to simulate the irradiation. Each patient will be irradiated three times per week for six weeks, totaling 18 sessions. Neuropsychological assessments will be held one week before the beginning of the sessions, after one week, and three months after the end of LLLT sessions. Memory domain, attention, executive functioning, and visual construction will be evaluated, in addition to symptoms of depression, anxiety, and social demographics. DISCUSSION: LLLT has been demonstrated as a safe and effective technique in significantly improving the memory, attention, and mood performance in healthy and neurologic patients. We expect that our trial can complement previous finds, as an effective low-cost therapy to improve cognitive sequel after TBI. TRIAL REGISTRATION: ClinicalTrials.gov, NCT02393079 . Registered on 20 February 2015.


Subject(s)
Anxiety/therapy , Brain Injuries, Traumatic/radiotherapy , Brain Injury, Chronic/radiotherapy , Brain/radiation effects , Depression/therapy , Low-Level Light Therapy/methods , Adolescent , Adult , Affect/radiation effects , Anxiety/diagnosis , Anxiety/physiopathology , Anxiety/psychology , Attention/radiation effects , Brain Injuries, Traumatic/diagnosis , Brain Injuries, Traumatic/physiopathology , Brain Injuries, Traumatic/psychology , Brain Injury, Chronic/diagnosis , Brain Injury, Chronic/physiopathology , Brain Injury, Chronic/psychology , Brazil , Depression/diagnosis , Depression/physiopathology , Depression/psychology , Double-Blind Method , Executive Function/radiation effects , Female , Humans , Low-Level Light Therapy/adverse effects , Male , Memory, Episodic , Middle Aged , Multicenter Studies as Topic , Neuropsychological Tests , Prospective Studies , Radiation Dosage , Randomized Controlled Trials as Topic , Time Factors , Treatment Outcome , Young Adult
17.
Photodiagnosis Photodyn Ther ; 21: 246-251, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29258951

ABSTRACT

BACKGROUND: Bovine mastitis is a disease that causes a severe drawback in dairy production. Conventional treatments with antibiotic could leave antibiotic residues in the milk. The aim of this study was to evaluate the effect of photodynamic therapy in the treatment of bovine subclinical mastitis to develop an in vivo therapeutic protocol that could be used in routine farm practice, favoring the early return to production. METHODS: Forty cows with subclinical mastitis (n = 40) were divided into 4 groups (control, photodynamic therapy - PDT, light irradiation - LED, and photosensitizer - PS). Control group received no treatment, PDT group received application of 1.0 mL of 2.5% toluidine blue photosensitizer followed by LED irradiation at λ = 635 nm, the LED group was treated with LED irradiation alone, and the PS group received only 2.5% toluidine blue dye. LED irradiation was applied to the mammary gland by means of an acrylic light guide coupled to the LED equipment. The PDT and LED groups were irradiated with 200 J/cm2 at three different positions inside the mammary gland. Milk samples were collected at 0 h, 12 h, 24 h after treatment for microbial identification and total bacterial count. RESULTS: The treatment of the PDT group showed significant difference p < 0.05, characterizing the efficiency of this technique with the reduction of the microorganisms Streptococcus dysgalactiae and coagulase-negative Staphylococcus. CONCLUSION: Photodynamic therapy was effective when applied in vivo for subclinical bovine mastitis. There was no need to separate the animal from production.


Subject(s)
Mastitis, Bovine/drug therapy , Photochemotherapy/methods , Photosensitizing Agents/therapeutic use , Tolonium Chloride/therapeutic use , Animals , Bacillus/drug effects , Cattle , Cell Count , Corynebacterium/drug effects , Escherichia coli/drug effects , Female , Mastitis, Bovine/microbiology , Milk/microbiology , Staphylococcus , Streptococcus/drug effects
18.
Braz. oral res. (Online) ; 32: e61, 2018. tab, graf
Article in English | LILACS | ID: biblio-974452

ABSTRACT

Abstract To evaluate the impact of the GaAlAs diode laser with energy densities of 160 J/cm2, 320 J/cm2, and 640 J/cm2 on the periodontal tissues under continuous orthodontic force application and on the rate of orthodontic tooth movement in rats with type-2 diabetes mellitus. The intensity of primary alveolar bone formation was also investigated through the immune-positive osteocytes for OPN antibody. Forty adult male Wistar rats were divided into eight groups of 5 rats: normoglycemic (N), 160 J-laser-normoglycemic (160 J-LN), 320 J-laser-normoglycemic (320 J-LN), 640 J-laser-normoglycemic (640 J-LN), diabetic (D), 160 J-laser-diabetic (160 J-LD), 320 J-laser-diabetic (320 J-LD), and 640 J-laser-diabetic (640 J-LD) rats. Diabetes mellitus was induced by a single intravenous injection of 40 mg/kg monohydrated-alloxan. An orthodontic force magnitude of 20cN was applied. The laser parameters were continuous emission of 780-nm wavelength, output power of 20mW, and fiber probe with a spot size of 0.04 cm in diameter. Radiographic, histomorphological, and immunohistochemical analysis were performed after a period of 21 days. The photobiomodulation using the energy density of 640 J/cm2 strongly stimulated the alveolar bone formation and contributed the reorganization of the soft periodontal tissues, followed by the 320 J/cm2. Extensive alveolar bone loss, intense infiltration of inflammatory cells, and degradation of the PDJ tissue were mainly found in the D and 160 J-LD groups. The rate of orthodontic tooth movement was represented by the interdental distance between the cementoenamel junctions of the right mandibular first and second molars . This distance was larger in the diabetic groups (D: 39.98±1.97, 160 J-LD: 34.84±6.01, 320 J-LD: 29.82±1.73, and 640 J-LD: 35.47±4.56) than in the normoglycemic groups (N: 21.13±1.19; 160 J-LN: 22.69±0.72, 320 J-LN: 22.28±0.78, and 640 J-LN: 24.56±2.11). The number of osteopontin-positive osteocytes was significantly greater in the 640 J-LD (14.72 ± 0.82; p < 0.01) and 640 J-LN (13.62 ± 1.33; p < 0.05) groups than with D (9.82 ± 1.17) and 160 J-LD (9.77 ± 1.10) groups. Therefore, the energy density of 640 J/cm2 provided the best maintenance and integrity of the periodontal tissue microarchitecture under continuous orthodontic force when compared with the other dosages, mainly in the uncontrolled diabetic rats. The interdental distance was greater in the D and 160 J-LD groups due to presence of severe periodontitis caused by diabetes plus the mechanical stress generated by continuous orthodontic forces, implying, thus, an insufficient biostimulatory effect for the dosage of 160 J/cm2.


Subject(s)
Animals , Male , Tooth Movement Techniques/methods , Periodontium/radiation effects , Low-Level Light Therapy/methods , Diabetes Mellitus, Type 2/physiopathology , Orthodontic Appliances , Osteoclasts/radiation effects , Osteocytes/radiation effects , Osteogenesis/radiation effects , Radiation Dosage , Reference Values , Periodontium/pathology , Periodontium/diagnostic imaging , Immunohistochemistry , Radiography , Random Allocation , Reproducibility of Results , Alveolar Bone Loss/pathology , Rats, Wistar , Diabetes Mellitus, Experimental , Osteopontin/analysis , Lasers, Semiconductor/therapeutic use
19.
Lasers Med Sci ; 32(7): 1479-1487, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28674791

ABSTRACT

The purposes of the present study are to assess the effects of the GaAlAs diode laser on the periodontal tissues and to investigate its action on the alveolar bone remodeling process during orthodontic tooth movement in normoglycemic and diabetic rats. Sixty adult male Wistar rats were divided into four groups of 15 rats: normoglycemic (N), diabetic (D), laser-normoglycemic (LN), and laser-diabetic (LD) rats. Diabetes mellitus was induced by a single intravenous injection of 40 mg/kg monohydrated alloxan. The orthodontically moved tooth underwent a force magnitude of 20 cN. The laser irradiation with a continuous emission of a 780-nm wavelength, an output power of 20 mW, and a fiber probe with a spot size of 0.04 cm in diameter and an area of 0.00126 cm2 were used. Moreover, an energy density of 640 J/cm2 was applied in an exposition time of 40 s. Histomorphological and immunohistochemical analysis was performed. The photobiomodulation (PBM) strongly stimulated the periodontal tissue response, establishing mainly the balance between the bone formation and resorption. Intense inflammatory cell infiltration and extensive loss of bone tissue were mainly found in the D group from 14 days. The number of osteopontin-positive osteocytes was significantly greater in the LN group, followed by the LD, especially at 7 and 14 days, whereas osteoprotegerin-positive osteoblasts were significantly higher in the LN and LD groups than in the N and D groups, respectively, in all periods. The PBM strongly stimulated the alveolar bone remodeling and favored the continuous reorganization of the soft periodontal tissues, leading to the maintenance and integrity of the periodontal microstructure under orthodontic force, especially in uncontrolled diabetic rats.


Subject(s)
Diabetes Mellitus, Experimental/pathology , Lasers, Semiconductor/therapeutic use , Orthodontics , Periodontium/radiation effects , Periodontium/surgery , Tooth Movement Techniques , Animals , Immunohistochemistry , Male , Osteoblasts/pathology , Osteoblasts/radiation effects , Osteoclasts/pathology , Osteoclasts/radiation effects , Osteopontin/metabolism , Osteoprotegerin/metabolism , Periodontium/pathology , RANK Ligand/metabolism , Rats, Wistar
20.
Lasers Med Sci ; 32(4): 787-795, 2017 May.
Article in English | MEDLINE | ID: mdl-28271376

ABSTRACT

Raman spectroscopy has been employed in the quantitative analysis of biochemical components in human serum. This study aimed to develop a spectral model to estimate the concentration of glucose and lipid fractions in human serum, thus evaluating the feasibility of Raman spectroscopy technique for diagnostic purposes. A total of 44 samples of blood serum were collected from volunteers submitted to routine blood biochemical assay analysis. The biochemical concentrations of glucose, triglycerides, cholesterol, and high-density and low-density lipoproteins (HDL and LDL) were obtained by colorimetric method. Serum samples (200 µL) were submitted to Raman spectroscopy (830 nm, 250 mW, 50-s accumulation). The spectra of sera present peaks related to the main constituents, particularly proteins and lipids. A quantitative model based on partial least squares (PLS) regression has been developed to estimate the concentration of these compounds, taking the biochemical concentrations assayed by the colorimetric method as sample's actual concentrations. The PLS model based on leave-one-out cross-validation approach estimated the concentration of triglycerides and cholesterol with r = 0.98 and 0.96, and root mean square error of 35.4 and 15.9 mg/dL, respectively. For the other biochemicals, the r was ranging from 0.75 to 0.86. These results evidenced the possibility of performing biochemical assay in blood serum samples by Raman spectroscopy and PLS regression and may be employed as a means of diagnosis in routine clinical analysis.


Subject(s)
Blood Glucose/analysis , Lipids/blood , Spectrum Analysis, Raman/methods , Colorimetry , Humans , Least-Squares Analysis , Multivariate Analysis , Reference Standards